Contribution of Neural Elements to Thoracic Stability

Department

neurosurgery

Document Type

Article

Abstract

Aim: Studies of spinal biomechanics typically do not focus on the contributions to range of motion (ROM) of the primary components of the spinal canal, dura, arachnoid, pia, spinal cord, nerve roots, ligaments, and vessels. We sought to determine the stability offered by these soft tissues in vitro. Material and Methods: Human cadaveric segments were tested intact, after osteoligamentous destabilization, and after transection of T8-9 spinal canal components. Specimens were induced into flexion, extension, axial rotation, and lateral bending using non-constraining, non-destructive pure moment while tracking motion response stereophotogrammetrically. The range of motion (ROM) was compared in each condition after adjusting for soft tissue creep. Results: After spinal canal element transection, ROM increased in all directions (mean 4.7%). This increase was most pronounced during lateral bending (p=0.055). The cumulative ROM from all directions of loading showed a statistically significant mean increase of 3.3% (p=0.040). ConclusIon: Sectioning of canal elements was found to cause a measurable increase in ROM. Although nonviable tissues were tested, living tissues are also likely to contribute to spinal stability.

Publication Date

2017

Publication Title

Turkish Neurosurgery

ISSN

1019-5149

Volume

27

Issue

4

First Page

631

Last Page

635

Digital Object Identifier (DOI)

10.5137/1019-5149.JTN.16614-15.2