Biomechanical comparison of anterior versus posterior lumbar threaded interbody fusion cages
Document Type
Article
Abstract
Study Design. Biomechanical flexibility tests were performed in specimens receiving anterior lumbar interbody fixation or posterior lumbar interbody fixation using dual threaded cages. Objectives. To determine differences in stability between anterior lumbar interbody fixation and posterior lumbar interbody fixation immediately after surgery and after fatigue. Summary of Background Data. No direct biomechanical comparison of lumbar fixation with threaded anterior lumbar interbody fixation or posterior lumbar interbody fixation cages has been performed previously. Methods. Sixteen anterior lumbar interbody fixation specimens and 16 posterior lumbar interbody fixation specimens underwent nondestructive biomechanical testing. Flexibility was assessed during applied flexion, extension, lateral bending, axial rotation, and anteroposterior shear before and after fixation and fatigue. After testing, specimens were dissected, and the quality of fixation was graded. Results. Variability in angular range of motion after fixation was greater than normal interspecimen variability by 89% after anterior lumbar interbody fixation and by 117% after posterior lumbar interbody fixation. During flexion-extension and lateral bending, posterior lumbar interbody fixation allowed a mean of 60% smaller neutral zones than anterior lumbar interbody fixation (P < 0.05, nonpaired Student t test). During axial rotation, anterior lumbar interbody fixation allowed 15% less range of motion than posterior lumbar interbody fixation unless facets were kept intact with posterior lumbar interbody fixation (6 of 16 specimens), in which case anterior lumbar interbody fixation allowed 41% greater range of motion than posterior lumbar interbody fixation. During anteroposterior shear, both anterior lumbar interbody fixation and posterior lumbar interbody fixation restrained range of motion to within 50% of normal. Anterior lumbar interbody fixation loosened, on average, 130% more with fatigue than posterior lumbar interbody fixation during anteroposterior shear. Conclusions. Both anterior lumbar interbody fixation and posterior lumbar interbody fixation provided inconsistent stability. Therefore, stand-alone anterior lumbar interbody fixation or posterior lumbar interbody fixation may often be ineffective clinically. During all modes of loading except axial rotation, posterior lumbar interbody fixation performed slightly better than anterior lumbar interbody fixation, perhaps due to deeper hole preparation and destruction of anterior stabilizers necessary for anterior lumbar interbody fixation. Avoiding resection of facets during posterior lumbar interbody fixation led to significantly better performance during axial rotation.
Keywords
Anterior lumbar interbody fixation, Biomechanics, Posterior lumbar interbody fixation, Threaded cages
Publication Date
2-1-2005
Publication Title
Spine
ISSN
03622436
Volume
30
Issue
3
First Page
302
Last Page
310
PubMed ID
15682011
Digital Object Identifier (DOI)
10.1097/01.brs.0000152155.96919.31
Recommended Citation
Vishteh, A. Giancarlo; Crawford, Neil R.; Chamberlain, Robert H.; Thramann, Jeffrey J.; Sung, Chan Park; Craigo, J. Bradley; Sonntag, Volker K.H.; and Dickman, Curtis A., "Biomechanical comparison of anterior versus posterior lumbar threaded interbody fusion cages" (2005). Translational Neuroscience. 832.
https://scholar.barrowneuro.org/neurobiology/832