Evaluation Of A Multiple Spin- And Gradient-Echo (Sage) Epi Acquisition With Sense Acceleration: Applications For Perfusion Imaging In And Outside The Brain
Department
neurobiology
Document Type
Article
Abstract
Perfusion-based changes in MR signal intensity can occur in response to the introduction of exogenous contrast agents and endogenous tissue properties (e.g. blood oxygenation). MR measurements aimed at capturing these changes often implement single-shot echo planar imaging (ssEPI). In recent years ssEPI readouts have been combined with parallel imaging (PI) to allow fast dynamic multi-slice imaging as well as the incorporation of multiple echoes. A multiple spin- and gradient-echo (SAGE) EPI acquisition has recently been developed to allow measurement of transverse relaxation rate (R2 and R2*) changes in dynamic susceptibility contrast (DSC)-MRI experiments in the brain. With SAGE EPI, the use of PI can influence image quality, temporal resolution, and achievable echo times. The effect of PI on dynamic SAGE measurements, however, has not been evaluated. In this work, a SAGE EPI acquisition utilizing SENSE PI and partial Fourier (PF) acceleration was developed and evaluated. Voxel-wise measures of R2 and R2* in healthy brain were compared using SAGE EPI and conventional non-EPI multiple echo acquisitions with varying SENSE and PF acceleration. A conservative SENSE factor of 2 with PF factor of 0.73 was found to provide accurate measures of R2 and R2* in white (WM) (rR2=[0.55-0.79], rR2*=[0.47-0.71]) and gray (GM) matter (rR2=[0.26-0.59], rR2*=[0.39-0.74]) across subjects. The combined use of SENSE and PF allowed the first dynamic SAGE EPI measurements in muscle, with a SENSE factor of 3 and PF factor of 0.6 providing reliable relaxation rate estimates when compared to multi-echo methods. Application of the optimized SAGE protocol in DSC-MRI of high-grade glioma patients provided T1 leakage-corrected estimates of CBV and CBF as well as mean vessel diameter (mVD) and simultaneous measures of DCE-MRI parameters Ktrans and ve. Likewise, application of SAGE in a muscle reperfusion model allowed dynamic measures of R2', a parameter that has been shown to correlate with muscle oxy-hemoglobin saturation.
Publication Date
1-1-2014
Publication Title
Magnetic Resonance Imaging
ISSN
0730725X
Volume
32
Issue
10
First Page
1171
Last Page
1180
Digital Object Identifier (DOI)
10.1016/j.mri.2014.08.032
Recommended Citation
Skinner, Jack T.; Robison, Ryan K.; Elder, Christopher P.; Newton, Allen T.; Damon, Bruce M.; and Quarles, C. Chad, "Evaluation Of A Multiple Spin- And Gradient-Echo (Sage) Epi Acquisition With Sense Acceleration: Applications For Perfusion Imaging In And Outside The Brain" (2014). Translational Neuroscience. 349.
https://scholar.barrowneuro.org/neurobiology/349